The return value seems unreliable, and, afterall probably doesn't represent reality.
Ths change causes the linear focus algorithm to assume that timer-based focusers
have moved the number of ms requested for their movement.
Details
Details
There should be no changes to standard focus algorithms.
The only change would be with timer-based focusers (e.g. FCUSB) using the Linear Algorithm.
This didn't work previously (as I relied on the return value from the Indi, which is apparently unreliable).
That focuser should now autofocus with the linear focus algorithm, now changed to v3.1 in the menu.
Diff Detail
Diff Detail
- Repository
- R321 KStars
- Branch
- linear-3.1-ignore-timer-return (branched from master)
- Lint
No Linters Available - Unit
No Unit Test Coverage - Build Status
Buildable 21532 Build 21550: arc lint + arc unit