Bugfix for focus looping with HFR setup
Summary: When using HFR limits to trigger focusing after a certain amount of frames, the Capture module runs into an endless loop if "In-Sequence HFR Check" is set to "1". This patch corrects it.
Test Plan:
Start KStars with simulators:
- Start an autofocus sequence so that autofocus succeeds.
- Create an image sequence with HFR limit set and with more than one frame. Set EKOS / Capture Parameter "In-Sequence HFR Check" to 1.
- Start the image sequence
Without this patch, the Capture module runs into an endless loop executing a re-focus, as soon as the first image has been captured.
Reviewers: mutlaqja, TallFurryMan
Reviewed By: mutlaqja
Subscribers: kde-edu
Tags: KDE Edu
Differential Revision: https://phabricator.kde.org/D23258